Appendix
Support, Warranty, Training Resources and Trouble-shooting
Customer Support
For support, please contact your local representative or Support at Tobii Dynavox. In order to receive assistance as quickly as possible, make sure you have access to your TD Pilot device and, if possible, an internet connection. You should also be able to supply the serial number of the device, which you find under the Adjustable Stand on the TD Pilot Base.
For further product information and other support resources, please visit the Tobii Dynavox website www.tobiidynavox.com.
Warranty
Please read the Manufacturer’s Warranty paper included in the package.
iPads purchased together with TD Pilot are not covered by this manufacturer's warranty
Tobii Dynavox does not warrant that the Software on the TD Pilot will meet your requirements, that the operation of the software will be uninterrupted or error-free, or that all software errors will be corrected.
Tobii Dynavox does not warrant that the TD Pilot will meet Customer requirements, that the operation of the TD Pilot will be uninterrupted, or that the TD Pilot is free from bugs or other defects. Customer acknowledges that the TD Pilot will not function for all individuals and in all light conditions.
Please read this User’s Manual carefully before using the device. The warranty is only valid if the device is used according to the User’s Manual. Disassembling the TD Pilot Base will void the warranty.
It is recommended to keep the original packaging materials for the TD Pilot.
If the device needs to be returned to Tobii Dynavox for Warranty-related issues or repair, it is beneficial that the original packaging or equivalent is used for shipping. Most shipping carriers require at least 2 inches of packing material around the device.
Note: Due to Joint Commission regulations, any shipping materials (including boxes) sent to Tobii Dynavox must be discarded.
Training Resources
No specific training is required for the safe and effective use of the primary operating functions of the TD Pilot.
Tobii Dynavox offers a range of training resources for the TD Pilot products and related communication products. You can find them on the Tobii Dynavox website, www.tobiidynavox.com, including Getting Started Guides, webinars and Software Training Cards. The TD Pilot Getting Started Guide and Software Training Cards are delivered with the TD Pilot device.
Trouble-shooting Guide
If the TD Pilot does not Power up
Connect the power supply and wait a couple of minutes to allow charging before trying to power up the device again. If the device does not start up correctly, please contact Customer Support. See Customer Support for contact information.
How do I carry out a Power Reset on the TD Pilot?
Hold down the power button of the device for 10 seconds. Doing so will power off the device regardless of what it was doing. To turn it back on, momentarily press the power button and the device will start up and turn on.
This will not reset the iPadOS device; that must be done as a separate step.
If the device does not start up correctly, please contact Customer Support. See Customer Support for contact information.
How can I tell if the TD Pilot Base is Connected to the iPadOS Device?
In iPadOS go to: Settings > General > About.
If the TD Pilot Base is powered on and properly connected to the iPad you should see Tobii Dynavox Pilot near the bottom.
Refining Eye Gaze
If you are having difficulty using eye gaze with the TD Pilot, this list of common issues and solutions may help you. Try one or more of the solutions, since sometimes a combination results in successfully resolving the problem.
Issue | Solution |
|---|---|
Eye tracker does not detect eyes. |
|
Accuracy is not good. |
|
Accuracy gets worse over time. |
|
Glare from glasses seems to be interfering. |
|
Pointer response lags. |
|
Difficulty holding dwell for sufficient time. |
|
Selections happen too fast or accidentally. |
|
Pointer is jumpy or drifts. |
|
Cannot see Pointer. |
|
AssistiveTouch Menu button interferes or distracts. |
|
Feeling of motion sickness. |
|
Experiencing eye strain or dryness. |
|
Eyes do not move together (strabismus). |
|
Involuntary eye movements (nystagmus). |
|
Compliance Information
| The TD Pilot is CE marked in accordance with Regulation (EU) 2017/745 (MDR) and complies with applicable harmonized standards and the General Safety and Performance Requirements (GSPR). |
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
Modifications not expressly approved by Tobii Dynavox could void the user’s authority to operate the equipment under FCC rules.
For P15B Equipment
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
For Portable Devices
FCC RF Radiation Exposure Statement:
- This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
- This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device was tested for typical hand held operations with the device contacted directly to the human body to the sides of the device. To maintain compliance with FCC RF exposure compliance requirements, avoid direct contact to the transmitting antenna during transmitting.
CE Statement
This product is CE marked as an accessory to a medical device in accordance with Regulation (EU) 2017/745 (MDR) and conforms to the applicable General Safety and Performance Requirements (GSPR).
Directives and Standards
The TD Pilot complies with the following directives:
- Medical Device Regulation (EU) 2017/745
- Low voltage Directive 2014/35/EU
- Electromagnetic Compatibility (EMC) Directive 2014/30/EU
- RoHS2 Directive 2011/65/EU
- WEEE Directive 2012/19/EU
- Reach Directive 2006/121/EC, 1907/2006/EC Annex 17
- ISO 14971:2019
- ISO 13485:2016
The TD Pilot device has been tested to comply with IEC/EN 60601-1 Ed 3.1, IEC/EN 62368-1, ISO 14971:2019 and other relevant standards for the intended markets.
Status LED Information
State | Meaning | |||
|---|---|---|---|---|
LED | Power Adapter Connected? | TD Pilot Power | TD Pilot Battery | iPad Battery |
OFF | NO | OFF | Unknown | |
OFF | YES | Charged | Unknown | |
BLUE | (YES) | Charging | Unknown | |
PULSING BLUE | (YES) | ON | Charging | |
PULSING GREEN | YES | Charged | ||
PULSING GREEN | NO | Discharging | ||
RED | - | FAULT | ||
Technical Specifications
Device
Model | TD Pilot |
|---|---|
Type | TD Pilot |
Operating System | Apple iPadOS |
CPU | Apple M4 chip (9-core CPU) or newer |
Storage | 256 GB |
Screen Resolution | 2752 x 2064 |
Screen Size | 13" |
Rear Display | 480 × 128 pixels |
Dimensions (WxHxD) TD Pilot | 30,4 × 25,5 × 9,0 cm 12.0 × 10.0 × 3.5 inches |
Weight TD Pilot | 2.11 kg 4.65 lbs |
Microphone | 1×Microphone |
Speakers | 2 × 10 W Closed Box Speakers |
Connectors | 1 × Thunderbolt/USB 4 (iPadOS device) 1 × USB-C 2 × 3.5 mm Switch connector interface, (Pin out for mono plug: Sleeve = Common ground, Tip = Signal) 1 × 3.5 mm” Headphone jack (stereo) with jack detection 1×USB-C Power Connector |
Buttons | 1 × Top button (iPadOS device) 1 × Volume up/down (iPadOS device) 1 × Power On 1 × Track Status |
Bluetooth® | Bluetooth 5.3 |
Eye Tracker (optional) | Tobii IS5TDL Module |
Expected Service Life | 5 years |
Typical Average Battery Run Time | ~10 hours |
Battery Charge Time | Maximum 4 h |
Deskstand | Integrated |
Mounting Systems Supported | Tobii Dynavox QR adapter plate for Daessy and REHAdapt |
Power Supply | 15VDC, 3A, 45 W or 20VDC, 3A, 60 W AC Adapter |
IP class | IP54 Pass for device only, with I/O covers in place. |
IP22 Without I/O covers. |
Power Adapter
Item | Specification |
|---|---|
Trademark | Tobii Dynavox |
Manufacturer | MEAN WELL Enterprise Co., Ltd |
Model Name | NGE60-TD |
Rated Input | 100-240Vac, 50/60Hz, 1.5-0.8A |
Rated Output | 5V/9V/12V/15V/20Vdc, 3A, 60W max |
Output Plug | Compatible with USB-C Power Delivery up to 60W |
Battery pack
Item | Specification | Remark |
|---|---|---|
Battery Technology | Li-Ion rechargeable battery pack with gas gauge (SMBus v1.1 interface) | |
Cell | 6× NCR18650GA | |
Battery Pack Capacity | 71,28 Wh | Initial capacity, new battery pack |
Nominal Voltage | 10.8 Vdc, 6600mAh | |
Charge Time | Maximum 4 h | Charge from 10 to 90% |
Cycle Life | 300 cycles | Minimum 75% of initial capacity remaining |
Allowable Operating Temperature | 0 – 45 °C, 45-85%RH | Charge condition |
-20 – 60 °C, 45-85%RH | Discharge condition | |
Storage Temperature | -20 – 35 °C, 45-85%RH | 1 year |
-20 – 40 °C, 45-85%RH | 6 months | |
-20 – 45 °C, 45-85%RH | 1 month | |
-20 – 50 °C, 45-85%RH | 1 week | |
Storage Time 1 | Maximum 6 months @ charge ≥ 40% |
|
| ||
Eye Tracker
If installed
Technical Specifications | Tobii IS5TDL Module |
|---|---|
Working Distance | 45 — 95 cm |
Freedom of Head Movement 1 | ˜20 × 20cm (7.9 × 7.9 inches) @ 50 cm from screen |
Positioning Distance (from screen) Track box size (Width × Height) Track box depth |
45 — 95 cm (20 — 37 in) 20 × 20 — 35 × 35 cm (7.9 × 7.9 — 13.8 × 13.8 in) 50 cm (19.7 in) |
Gaze Data Rate | 33 Hz |
Gaze Sample Rate | 133 Hz |
Eye tracking technique | Video-based pupil- and corneal- reflection eye tracking with dark and bright pupil illumination modes. |
Outdoor Usage Possible | Yes |
User Calibration |
|
Detect Gaze Interaction >30Hz |
98% for 95% of population2 |
Gaze Accuracy Across 95% of population3 |
<1.58 degrees |
Gaze Precision Across 95% of population3 |
<0.2° |
Max Head Movement Speed Eye Position Gaze Data |
40 cm/s (15.7 in/s) 10 cm/s (3.9 in/s) |
Max Head Tilt | 25° |
Max Yaw, pitch | 25° |
Data Flow and Data Rate Gaze Latency Gaze Recovery |
17 ms 0 ms |
Mounting | Built-in |
Power Supply | Built-in |
| |
Guidance and Manufacturer’s Declaration
Below cables information are provided for EMC reference
Cable | Max. cable length | Shielded/unshielded | Number | Cable classification |
|---|---|---|---|---|
AC Power Cord | 0.9 m | Unshielded | 1 Set | AC Power |
DC Power Cord | 1.65 m | Shielded | 1 Set | DC Power |
Two Switch Button Cables | 1.44 m | Shielded | 1 Set | Signal |
USB cable | 0.26 m | Shielded | 1 Set | Signal |
Important information regarding Electro Magnetic Compatibility (EMC)
This electrical medical equipment needs special precautions regarding EMC and put into service according to the EMC information provided in the user manual; The equipment conforms to this IEC 60601-1-2:2014+A1:2020 standard for both immunity and emissions. Nevertheless, special precautions need to be observed:
- The equipment with no ESSENTIAL PERFORMANCE is intended used in Home healthcare environment.
- WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally”.
- The use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
- WARNING: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the TD Pilot, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.”
- WARNING: If the use location is near (e.g. less than 1.5 km from) AM, FM or TV broadcast antennas, before using this equipment, it should be observed to verify that it is operating normally to assure that the equipment remains safe with regard to electromagnetic disturbances throughout the expected service life.
STATEMENT: For the purpose of its operation, the equipment has wireless communication function, it includes RF transmitter and receiver, 2.4 GHz, Pulse modulation.
STATEMENT: The equipment is designed compatible with high frequency surgical equipment; the condition includes working or standby in close proximity to high frequency surgical equipment.
Phenomenon | Compliance | Electromagnetic environment |
|---|---|---|
RF emissions | CISPR 11 Group 1, Class B | Home healthcare environment |
Harmonic distortion | IEC 61000-3-2 Class A | Home healthcare environment |
Voltage fluctuations and flicker | IEC 61000-3-3 Compliance | Home healthcare environment |
Phenomenon | Basic EMC standard | Immunity test levels |
|---|---|---|
Home healthcare environment | ||
Electrostatic Discharge | IEC 61000-4-2 | ±8 kV contact |
Radiated RF EM field | IEC 61000-4-3 | 10 V/m |
Proximity fields from RF wireless communications equipment | IEC 61000-4-3 | Refer to table |
Rated power frequency magnetic fields | IEC 61000-4-8 | 30A/m |
Test frequency (MHz) | Band (MHz) | Immunity test levels |
|---|---|---|
Home healthcare environment | ||
385 | 380-390 | Pulse modulation 18Hz, 27V/m |
450 | 430-470 | FM, ±5kHz deviation, 1kHz sine, 28V/m |
710 | 704-787 | Pulse modulation 217Hz, 9V/m |
745 | ||
780 | ||
810 | 800-960 | Pulse modulation 18Hz, 28V/m |
870 | ||
930 | ||
1720 | 1700-1990 | Pulse modulation 217Hz, 28V/m |
1845 | ||
1970 | ||
2450 | 2400-2570 | Pulse modulation 217Hz, 28V/m |
5240 | 5100-5800 | Pulse modulation 217Hz, 9V/m |
5500 | ||
5785 |
Phenomenon | Basic EMC standard | Immunity test levels |
|---|---|---|
Home healthcare environment | ||
Electrical fast transients/burst | IEC 61000-4-4 | ±2 kV |
Surges Line-to-line | IEC 61000-4-5 | ±0.5 kV, ±1 kV |
Conducted disturbances induced by RF fields | IEC 61000-4-6 | 3V, 0.15 MHz - 80 MHz |
Voltage dips | IEC 61000-4-11 | 0% UT; 0.5 cycle |
0% UT; 1 cycle | ||
Voltage interruptions | IEC 61000-4-11 | 0% UT; 250/300 cycles |
Phenomenon | Basic EMC standard | Immunity test levels |
|---|---|---|
Home healthcare environment | ||
Conducted disturbances induced by RF fields | IEC 61000-4-6 | 3V, 0.15 MHz - 80 MHz |
Approved Accessories
Description | Model | Tobii Dynavox Part No. |
|---|---|---|
TD Pilot AC Adapter (Power Supply) | NGE60-TD | 1000769 |
Battery pack | TDBW1 | 13000162 |
Eye Gaze for TD Pilot | Tobii IS5L Module | 520223 |
For information about the latest approved Tobii Dynavox Accessories, please visit the www.tobiidynavox.com website or contact your local Tobii Dynavox reseller.
Local Certification Partners
The listed companies are the partners for our local certifications in their countries.
Contact Information: | |
Swiss Authorized Representative +41 44 597 50 55 | SOLUCIONES EN TECNOLOGÍA ADAPTADA MEXICO S.A DE C.V +1-800-344-1778 |
Adjusting dwell time in iPadOS Settings affects AssistiveTouch only. Adjusting dwell time in TD Talk or TD Snap affects your communication software only.
Do not store battery packs for a long time with less than 40% charge level.